Biblioteca Digital da UEM: Sistema Nou-Rau
Pgina Principal  Portugus   English  Español   Aumentar Texto  Texto Normal  Diminuir Texto
  Principal | Apresentao | Objetivos | Instrues Autores | Estatsticas | Outras Bibliotecas Digitais
  Sistema Integrado de Bibliotecas - SIB / UEM
Entrar | acessos | verso 1.1  
ndice
Pgina principal
Documentos
Novidades
Usurios

Aes
Consultar
Procurar
Exibir estatsticas

Procurar por:
Procura avanada

Dvidas e sugestes


Consultar: Programa de Ps-Graduao em Fsica (Acadmico)

Incio > Dissertaes e Teses > Cincias Exatas e da Terra > Fsica > Programa de Ps-Graduao em Fsica (Acadmico)

Ttulo [PT]: Desenvolvimento de um sistema para caracterizao de sensores de gases
Autor(es): Andre Luiz de Lima Ponzoni
Palavras-chave [PT]:

Termoeletroresistometria. Fsica. Gs. Sensor.
rea de concentrao: Fsica da Matria Condensada
Titulao: Mestre em Fsica
Banca:
Suzana Nbrega de Medeiros [Orientador] - UEM
Geraldo Roberto Carvalho Cernicchiaro - CBPF
Jos Roberto Dias Pereira - UEM
Resumo:
Resumo: Um sistema para caracterizao de amostras por termoeletroresistometria (TER) foi desenvolvido, incluindo-se tambm o cdigo fonte do programa de aquisio de dados para tal sistema. TER consiste na medida da resistncia eltrica em funo da temperatura. O sistema foi testado para amostras constitudas de misturas de xidos obtidas aps tratamentos trmicos de ps-liofilizados. Misturas de ps de hematita (Fe2O3) e acetato de mangans tetrahidratado [(CH3COO)2Mn4H2O], com uma razo molar dos ctions Fe:Mn=2:1, foram obtidas por liofilizao. Os ps-liofilizados foram tratados termicamente em ar por duas horas, em trs diferentes temperaturas. Para a amostra tratada termicamente a 400 C/2h, os espectros de difrao de raios X (DRX) indicaram a presena das fases hematita e hausmanita (Mn3O4). Para as amostras tratadas a 700 e 1000 C, DRX indicou a presena das fases xido de mangans (Mn2O3) e hematita, e xido de mangans ferro (FeMnO3) e hematita, respectivamente. TER mostrou que a amostra tratada a 400 C sensvel ao gs metano (CH4). Porm, esta sensibilidade s ocorre na condio especfica de baixa presso atmosfrica e na presena exclusiva do gs.

Abstract: A system for samples characterization by thermoelectroresistometry (TER) was developed, including the code for the acquisition data program for such system. TER consists on the measure of the electric resistance in function of the temperature. The system was tested for samples of oxides mixtures achieved after a thermal treatment of the freeze-dried powders. Mixtures of powders of hematite (Fe2O3) and manganese acetate tetra-hydrated [(CH3COO)2Mn4H2O], with a molar ratio for cations of Fe:Mn=2:1, were obtained by freeze-drying. The freeze-dried powders were thermal treated at 400 C/2h, the X-ray diffraction (XRD) spectra indicate the presence of hematite and hausmanite (Mn3O4). For the samples treated at 700 and 1000 C, XRD indicated the presence of manganese oxide (Mn2O3) and hematite, and iron manganese oxide (FeMnO3) and hematite phases, respectively. TER showed that the sample treated at 400 C is sensitive to methane gas (CH4). Nevertheless, the sensitivity only occurs in the specific condition of low atmospheric pressure and in the exclusively presence of the gas.
Data da defesa: 25/04/2007
Cdigo: vtls000166603
Informaes adicionais:
Idioma: Portugus
Data de Publicao: 2007
Local de Publicao: Maring, PR
Orientador: Prof. Dr. Suzana Nbrega de Medeiros
Co-Orientador: Prof. Dr. Jusmar Valentin Bellini
Instituio: Universidade Estadual de Maring. Departamento de Fsica
Nvel: Dissertao (mestrado em Fsica)/
UEM: Programa de Ps-Graduao em Fsica

Responsavel: inez
Categoria: Aplicao
Formato: Documento PDF
Arquivo: andre_luiz_lima_ponzoni_2007_noPW.pdf
Tamanho: 3383 Kb (3464256 bytes)
Criado: 23-07-2010 08:46
Atualizado: 23-07-2010 09:09
Visitas: 1014
Downloads: 11

[Visualizar]  [Download]

Todo material disponvel neste sistema de propriedade e responsabilidade de seus autores.