Biblioteca Digital da UEM: Sistema Nou-Rau
Pgina Principal  Portugus   English  Español   Aumentar Texto  Texto Normal  Diminuir Texto
  Principal | Apresentao | Objetivos | Instrues Autores | Estatsticas | Outras Bibliotecas Digitais
  Sistema Integrado de Bibliotecas - SIB / UEM
Entrar | acessos | verso 1.1  
ndice
Pgina principal
Documentos
Novidades
Usurios

Aes
Consultar
Procurar
Exibir estatsticas

Procurar por:
Procura avanada

Dvidas e sugestes


Consultar: Programa de Ps-Graduao em Engenharia Qumica

Incio > Dissertaes e Teses > Engenharias > Engenharia Qumica > Programa de Ps-Graduao em Engenharia Qumica

Ttulo [PT]: Tratamento de efluentes da indstria textil por coagulao e floculao utilizando polmeros naturais
Autor(es): Osrio Moreira Couto Jnior
Palavras-chave [PT]:

Efluentes. Indstria txtil. Tratamento. Coagulao/floculao. Tanino e Moringa olefera. Sulfato de alumnio. Brasil.
Palavras-chave [EN]:
Textile effluent. Coagulation/flocculation. Tannin. Moringa oleifera Lam.
Aluminum Sulfate. Brazil.
rea de concentrao: Desenvolvimento de Processos
Titulao: Mestre em Engenharia Qumica
Banca:
Nehemias Curvelo Pereira [Orientador] - UEM
Maria Anglica Simes Dornellas de Barros [Co-orientador] - UEM
Gabriel Francisco da Silva - UFS
Miriam Carla Bonicontro Ambrosio Ugri
Resumo:
Resumo: Os efluentes de estamparias industriais, de maneira geral, contm sujeiras removidas das roupas, e substncias adicionadas, devido aplicao direta e fixao dos corantes e pigmentos no tecido, que normalmente so tratados por processos fsico-qumicos de coagulao/floculao e sedimentao. O coagulante qumico, Sulfato de Alumnio muito empregado no tratamento de efluentes txteis, devido a boa eficincia na coagulao das partculas coloidais e a seu baixo custo de aplicao. No entanto, este reagente qumico no biodegradvel e pode trazer srios riscos sade humana, dependendo da concentrao em que estiver presente na gua. Muitos dos tratamentos de efluentes tem sido desenvolvidos e investigados adotando o uso de coagulantes naturais, por apresentarem vantagens em relao aos coagulantes qumicos, principalmente devido biodegrabilidade e baixa produo de lodo residual. No entanto, neste trabalho foram realizados ensaios de coagulao/floculao e sedimentao, objetivando a otimizao do tratamento de efluente de uma estamparia industrial, utilizando coagulante qumico: o Sulfato de Alumnio e coagulantes naturais: Tanino e Moringa oleifera Lam. Os ensaios foram realizados em aparelho "jar test", variando-se os tempos de misturas, sedimentao e a concentrao dos coagulantes. As amostras foram sujeitas a um perodo inicial de mistura rpida (95 rpm), em seguida mistura lenta (35rpm) e repouso para sedimentao. Aps a coaguao/floculao e sedimentao, os sobrenadantes foram transferido para outros recipientes para posterior analises. Os efluentes brutos e tratados na estamparia foram coletados e caracterizados com os mesmos parmetros realizados para os testes de coagulao/floculao, apresentando-se sempre em elevadas quantidades em termos de matria orgnica, expressa em DQO. Foram feitos testes de alcalinidade, acidez voltil, cor, DBO5, DQO, metais, pH, slidos e turbidez. As concentraes timas encontradas foram de 400 mg/L, 600 mg/L e 2500 mg/L para o Tanino, Sulfato de Alumnio e Moringa oleifera Lam, respectivamente. Observou-se que o tratamento utilizando o Tanino foi o mais eficiente alcanando remoes de 99,17% de Cor, 99,65% de Turbidez, 92,72% de DBO5, 94,81% de DQO, 47,85% de Slidos Totais, e 96,67% de Slidos Suspensos Totais em relao ao efluente bruto. Dentre todos os metais removidos, se verifica que o mercrio e mangans tiveram uma remoo superior a 60% pelos coagulantes e remoes inferiores a 30% foram encontradas apenas para o cromo e a prata, com exceo do Tanino para este, que obteve uma remoo superior. Pode-se concluir que o Tanino apresentou o melhor resultado em termos dos parmetros investigados e menor custo econmico em relao ao coagulante qumico, Sulfato de Alumnio, permitindo uma economia maior que 22% ao ms.

Abstract: The effluents of industrial screen printers, in general, contain debris removed from the clothes, and substances added, due to the direct application and fixation of dyes / pigments in the tissue, which are usually treated by physical and chemical processes of coagulation / flocculation and sedimentation. The chemical coagulant, aluminum sulfate is widely used in the treatment of textile effluents, due to good performance in the coagulation of colloidal particles and their low cost of implementation. However, this reagent chemical is not biodegradable and can pose serious risks to human health, depending on the concentration that is present in the water. Many of the effluent treatment has been developed and investigated by adopting the use of natural coagulants, since they have advantages over chemical coagulants, mainly due to biodegradation and low production of sludge waste. However, this study tests were performed coagulation/flocculation and sedimentation, in order to optimize the treatment of effluent from an industrial stamping, using chemical coagulant, aluminum sulfate and natural coagulants: Tannin and Moringa oleifera Lam. The tests were performed on apparatus jar test, varying the times of mixtures, sedimentation and concentration of coagulants. The samples were subjected to an initial period of rapid mixing (95 rpm), then blend slowly (35rpm) and rest for sedimentation. After coagulation / flocculation and sedimentation, the supernatants were transferred to other containers for later analysis. Raw and treated effluents in the printing collections were made and characterized with the same parameters for the tests performed in coagulation / flocculation, appearing always in high quantities in terms of organic matter expressed as COD. During tests of alkalinity, acidity, color, BOD5, COD, metals, pH, solids and turbidity. The optimal concentrations found were 400 mg /L, 600 mg /L and 2500 mg /L for Tannin, aluminum sulfate, and Moringa oleifera Lam, respectively. It was observed that treatment using the tannin was the most efficient removal of 99.17% reaching Color, 99.65% of Turbidity, 92.72% of BOD5, COD 94.81%, 47.85% Solids Total, and 96.67% of total suspended solids over the effluent. Among all the metal removed, it appears that the metals mercury and manganese had a greater than 60% removal by coagulants and removals of less than 30% were found only for chromium and silver, except for this Tannin, who achieved a higher removal. It can be concluded that the tannin showed the best results in terms of parameters investigated and lower economic costs in relation to chemical coagulant, aluminum sulfate, allowing savings of up to 22% per month.
Data da defesa: 15/02/2011
Cdigo: vtls000184988
Informaes adicionais:
Idioma: Portugus
Data de Publicao: 2011
Local de Publicao: Maring, PR
Orientador: Prof. Dr. Nehemias Curvelo Pereira
Co-Orientador: Prof. Dr. Maria Anglica Simes Dornellas de Barros
Instituio: Universidade Estadual de Maring. Departamento de Engenharia Qumica
Nvel: Dissertao (mestrado em Engenharia Qumica)/
UEM: Programa de Ps-Graduao em Engenharia Qumica

Responsavel: beth
Categoria: Aplicao
Formato: Documento PDF
Arquivo: Dissertacao-Osorio-Final.pdf
Tamanho: 4230 Kb (4331836 bytes)
Criado: 31-05-2011 12:35
Atualizado: 31-05-2011 12:52
Visitas: 1917
Downloads: 128

[Visualizar]  [Download]

Todo material disponvel neste sistema de propriedade e responsabilidade de seus autores.