Ttulo [PT]: Anlise do comportamento estrutural de postes de concreto armado utilizados em linhas de transmisso de energia eltrica
Autor(es): Paulo Ferreira Benencase
Palavras-chave [PT]:

Concreto armado, Postes, Concreto armado, Comportamento estrutural, Energia eltrica, Linhas de transmisso - Brasil
Palavras-chave [EN]:
Reinforced concrete poles. Transmission lines. Structural behavior. - Brazil
rea de concentrao: Engenharia de Estruturas
Titulao: Mestre em Engenharia Civil
Banca:
Romel Dias Vanderlei [Orientador] - UEM
Anamaria Malachini Miotto Farah - UEM
Joo Dirceu Nogueira Carvalho - UNING
Resumo:
Resumo: O uso de postes de concreto armado em linhas de transmisso de energia eltrica apresenta vantagens com relao ao uso de torres metlicas, tais como: fundaes mais econmicas; maior rapidez na montagem; menor necessidade de rea para instalao; maior durabilidade frente s intempries; maior resistncia ao fogo; menor necessidade de manuteno e melhor aspecto visual. Porm, o seu emprego recente e a literatura sobre o assunto ainda escassa. O presente trabalho aborda de maneira ampla os critrios envolvidos no projeto deste tipo de estrutura e tem como objetivo demonstrar os procedimentos de clculo estrutural e avaliar o desempenho de postes com diferentes formatos. Nele realizado o dimensionamento de postes com 23 metros de altura e diferentes geometrias: seo circular vazada, seo retangular vazada e seo duplo T, de acordo com as normas tcnicas brasileiras ABNT NBR 5422:1985, ABNT NBR 6123:1988, ABNT NBR 6118:2014 e ABNT NBR 8451:2011. A anlise estrutural dos postes complementada com a realizao de simulaes numricas com auxlio do software ABAQUS que se baseia no Mtodo dos Elementos Finitos. Os resultados obtidos, tais como: esforos, tenses, deslocamentos, armaduras e peso das estruturas foram comparados, a fim de se evidenciar as principais vantagens e desvantagens de cada formato de poste. Com isso, foi possvel constatar para os casos propostos que o poste de seo circular vazada absorveu menos carga de vento, demandou o menor quantitativo de ao e teve a menor taxa de armadura, o poste de seo duplo T acusou os maiores esforos, mas o menor volume de concreto, o poste de seo retangular vazada apresentou alto consumo de materiais e foi a segunda estrutura mais pesada

Abstract: The use of reinforced concrete poles for electric power transmission lines has advantages with respect to the use of steel towers, such as more economic foundations; increased speed o assembly; need smaller area for installation; durability in the face of bad weather; higher fire resistance; lower maintenance and better visual appearance. However, its use is recent and the literature on the subject still scarce. This paper discusses broadly the criteria involved in the design of this type of structure and aims to demonstrate the structural calculation procedures and evaluate the performance of posts with different formats. In this, are designed poles with 23 meters high and different geometries: circular hollow section, rectangular hollow section and double Tsection, according to the Brazilian technical standards NBR 5422:1985, NBR 6123:1988, NBR 6118:2014 and NBR 8451:2011. Structural analysis of the poles is complemented with the development of numerical simulations with the aid of ABAQUS software that is based on the Finite Element Method. The results obtained, such as efforts, stresses, deflections and weight of armor were compared in order to highlight the main advantages and disadvantages of each post format. As a result, it was found that for the proposed cases the pole with a hollow circular section absorbs less wind load, required the least amount of steel and also had the lowest rate of reinforcement, the pole with a double T section accused the greatest efforts but the lowest volume of concrete, the pole with a hollow rectangular section showed high consumption of materials and was the second heaviest structure
Data da defesa: 29/09/2015
Cdigo: vtls000223535
Informaes adicionais:
Idioma: Portugus
Data de Publicao: 2015
Local de Publicao: Maring, PR
Orientador: Prof. Dr. Romel Dias Vanderlei
Instituio: Universidade Estadual de Maring . Centro de Tecnologia . Programa de Ps-Graduao em Engenharia Civil
Nvel: Dissertao (mestrado Engenharia Civil)
UEM: Departamento de Engenharia Civil

Responsavel: luiz
Categoria: Aplicao
Formato: Documento PDF
Arquivo: Dissertao Mestrado PCV - Paulo F. Benencase.pdf
Tamanho: 7822 Kb (8009221 bytes)
Criado: 09-09-2016 07:50
Atualizado: 09-09-2016 07:54
Visitas: 975
Downloads: 79

[Visualizar]  [Download]

Todo material disponvel neste sistema de propriedade e responsabilidade de seus autores.